Exact question counts, passing scores, and allowed reference materials vary by testing window and state/agency. Always confirm current rules with the official testing provider.
Sample questions
A 20,000 sq ft single-story Business (Group B) office building includes a 1,600 sq ft employee cafeteria and lounge classified as Group A-2 Assembly. Under IBC Section 508.2, how may this cafeteria be regulated if it is not separated by a fire barrier from the surrounding offices?
It requires a 2-hour fire barrier wall as a Separated Occupancy because Group A-2 is an assembly use.
It forces the entire 20,000 sq ft building to satisfy the stricter Group A-2 height and area rules.
It is exempt from all egress, fire-extinguishing, and occupant load rules because it serves internal employees rather than the general public.
It qualifies as an Accessory Occupancy (8% of story area, <= 10% limit), requiring no fire barrier separation.
Show the answer
D. It qualifies as an Accessory Occupancy (8% of story area, <= 10% limit), requiring no fire barrier separation.
Under IBC Section 508.2, an occupancy ancillary to the main occupancy that occupies no more than 10% of the building area of the story in which it is located (here 1,600 / 20,000 = 8.0% <= 10%) and does not exceed tabular allowable area limits for its own occupancy qualifies as an Accessory Occupancy. No fire-resistance-rated separation is required between an accessory occupancy and the main occupancy (except for Group H and specific incidental uses), though the space itself must still meet its own Group A-2 egress and occupant load rules.
Reference: International Building Code (IBC 2021/2024) Section 508.2 (Accessory Occupancies)
Where should a low-permeance vapor retarder be positioned in a wood-framed exterior wall in a cold, heating-dominated climate (ASHRAE Climate Zone 6) compared to a hot-humid, cooling-dominated climate (ASHRAE Climate Zone 1A)?
On the warm-in-winter interior side in Zone 6, and toward the exterior side (avoiding interior vinyl wallcoverings) in Zone 1A.
On the exterior cold side behind cladding in Zone 6 to block rain, and directly behind interior gypsum board in Zone 1A to trap cooled air.
On both the interior and exterior faces of the stud cavity in both climates to create a doubly sealed assembly against bidirectional diffusion.
Centered inside the fiberglass batt insulation in Zone 6, and omitted from all roof and slab assemblies in Zone 1A.
Show the answer
A. On the warm-in-winter interior side in Zone 6, and toward the exterior side (avoiding interior vinyl wallcoverings) in Zone 1A.
Water vapor diffuses from the warm, high-vapor-pressure side toward the cold, low-vapor-pressure side. In a cold heating-dominated climate (Zone 6), winter vapor drive is outward, so a vapor retarder goes on the warm-in-winter (interior) side (or exterior continuous insulation keeps the sheathing warm). In a hot-humid climate (Zone 1A), vapor drive is inward toward air-conditioned interiors, so low-permeance layers belong toward the exterior—and interior vapor barriers (such as vinyl wallcoverings) must be avoided to prevent condensation and mold behind the finish. Double vapor barriers trap moisture and prevent drying.
An architect is reviewing a single-user accessible restroom plan for compliance with the 2010 ADA Standards. The in-swinging entry door has both a closer and a latch and is approached from the front on both sides. Which combination of wheelchair turning space and door latch-side maneuvering clearances meets ADA minimums?
D. 60-inch turning circle, 18-inch pull-side latch clearance, and 12-inch push-side latch clearance.
Under the 2010 ADA Standards Section 304.3.1, circular wheelchair turning space must be at least 60 inches in diameter (or an equivalent T-shaped turning space). Under Table 404.2.4.1 for a front approach to a swinging door, the pull side requires 60 inches perpendicular depth and at least 18 inches of latch-side clearance; the push side requires 48 inches perpendicular depth and 12 inches of latch-side clearance whenever the door is equipped with both a closer and a latch.
Reference: 2010 ADA Standards for Accessible Design Sections 304.3 & 404.2.4.1 (Table 404.2.4.1)